Your One Stop for All Chemicals
Industrial • Marine • Cleaning
+968 9822 9755 / +968 9948 9269
WhatsApp / Call Us Anytime
omanchem.com@gmail.com
Drop Us a Line
Muscat, Sultanate of Oman
Locate Us

Lab Chemical-60

Educational Use Only - Order On Request

AESCULIN

Product Code: RXSOL-60-6524-001

Product Short Description

AESCULIN

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

ADENOSINE FOR BIOCHEMISTRY

Product Code: RXSOL-60-6523-001

Product Short Description

ADENOSINE FOR BIOCHEMISTRY

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

ADENINE SULPHATE AR

Product Code: RXSOL-60-6522-001

Product Short Description

ADENINE SULPHATE AR

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

ACRYLAMIDE FOR SYNTHESIS

Product Code: RXSOL-60-6515-001

Product Short Description

ACRYLAMIDE FOR SYNTHESIS

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

Alcohol Based Advance Disinfectant Cleaner

Product Code: RXSOL-60-6391-025

Product Short Description

Advance Laboratory disinfectant is an all-purpose, alcohol based formulation. This new formulation is based on micro-emulsion technology, providing a safer, simpler and more secure disinfectant that is economical to use.

Remarks

Alcohol Based Advance Disinfectant Cleaner  contains 5 Powerful Actives and offers Real & Proven 99.999% Germ Kill with Anti-Bacterial, Anti-Viral, Anti-Mold, Anti-Mildew, Anti-Fungal Protection against most Disease-Causing Germs including Viruses. .

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

Potassium Ferrocyanide NOT FOR SALE

Product Code: RXSOL-60-5126-025

Product Short Description

Potassium Ferrocyanide

Remarks

Detecting free Iron :   Spray the surface with a solution of potassium ferricyanide. If free iron is present, a blue color will appear. This test is extremely sensitive and often gives false positive results, that is, it gives an indication of iron being present when it really is not. The ferroxyl solution must be made fresh each day by addition with Nitric acid. The ferroxyl tests are described in ASTM A380.

Other Equivalent Brand

Red prussiate, Prussian red, Potassium hexacyanoferrate(III)

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

Distilled Water Lab Pure

Product Code: RXSOL-60-2212-050

Product Short Description

High Quality steam distilled water for lab Reagent and research.

Other Equivalent Brand

Battery Grade, Purified Water

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

Copper (II) Carbonate

Product Code: RXSOL-60-6090-500

Product Short Description

This bluish green powder is soluble in acids and insoluble in water

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

Acidity Water Test

Product Code: RXSOL-60-5515-004

Product Short Description

Test for acidity of water

Remarks

1. Method of pH indicator

In this method, various indicators are used. An indicator develops a particular colour when added to the solution depending upon the pH of the solution. e.g. phenolphthalein, an acid-base indicator, is colourless below a pH of 8.3 and distinctly pink above pH 10.0. Thus, it shows distinctly different colours below and above a small pH range.
2.
Electro motive force (e.m.f.) method or potentiometric method:

Here the e.m.f. of a cell, consisting of standard reference electrode and an electrode reversible to H+ ions is measured. As the H+ ion concentration changes, the values of e.m.f. of the cell change.

pH is then calculated from the observed values of e.m.f. of the cell or it may be obtained directly by using a pH meter.

The electrode whose potential is dependent upon the concentration of the ions to be determined, is termed as indicator electrode. There are various types of indicator electrodes e.g. hydrogen electrode, glass electrode, quinhydrone electrode etc. The choice of indicator electrode depends upon the type of reaction which is under investigation.

When H+ ions are involved or in case of acid-base titration, the indicator electrode which may be hydrogen electrode or some other hydrogen on responsive electrode like glass electrode is used.

Glass electrode consists of a very thin walled glass bulb blown at the end of the glass tube. The bulb contains an electrode which has a constant potential (e.g. a platinum wire coated with Ag/AgCl dipping in 0.1N HCl solution or a platinum wire dipping in 0.1N HCl solution saturated with quinhydrone.) When the glass surface of the bulb is kept in contact with a solution, it acquires a potential which depends upon H+ ion concentration of the solution.

The pH meter is essentially a voltage measuring device so designated that it can be used with cells of high resistance (e.g. glass electrode which has a very high resistance and a standard calomel electrode as the reference electrode).

There are two common types of pH meters, one is potentiometric and second is direct reading type.

The operating instructions vary from instrument to instrument. The general procedure for a typical instrument is given below.
General procedure

It includes the following steps:
I. Preparation of standard buffer solutions

For acidic range having a pH 4.0 at 25 0 C :

1.021g of potassium hydrogen phthalate (or specific standard buffer tablet) is dissolved in a minimum quantity of distilled water (the solution may warmed if necessary). The solution is cooled and dilute to 100 ml with distilled water in a standard measuring flask and shake well.

2. For alkaline range having a pH of 9.2 at 25 0 C :

0.381 g of borax (or the standard buffer tablet) is dissolved in a minimum quantity of distilled water ( the solution may be warned if required ).The solution is cooled and dilute it to 100 ml with distilled water in a standard measuring flask and shake well.
II. Preliminary setting of pH meter

1. The electrodes are washed with distilled water. Washing is done with the help of a polythene wash bottle. Dry the electrodes carefully of by absorbing the water drops with the help of filter paper.
2. Fix both the electrodes in the electrode clip and connect them to proper terminals ( sometimes there is only one combined electrode in incorporating both the electrodes ).

3.The range selector is kept at a the zero position ( or in stand by position ).
4. Switch the instrument on and then wait for a few minutes.
5. At this stage, the pointer on the scale should read pH 7 ( or 0 mV ). If thepointerisnotonpH7(or0mV),thansetthepointer toreadpH7 by turning the set zero control.

III. Standardisation or Calibration of pH meter

1. Take the standard buffer pH 4.01 solution in a clean 100 ml beaker. The electrodes are carefully lowered in this solution ( about one inch deep ).
2. Measure the temperature of the solution and set the temperature compensate control at measured temperature.

3. Set the range selector switch to pH range 0 – 7 position.
4. At this stage, reading in the scale should indicate pH of the buffer solution i.e. pH 4.01. If it shows other reading, then bring the pointer to 4.01, by turning the set buffer control knob. This is the standardisation of pH meter in acidic rang.
5. Remove the electrode from buffer solution and wash them thoroughly with distilled water.
6. Take a standard buffer ( pH 9.2 ) solution in a clean 100 ml beaker. Dip the cleaned electrode in this solution ( about one inch deep ).
7. Measure the temperature of the solution and set the temperature compensate control at measured temperature.
8. Set the range selector switch to pH range 7 – 14 position. Pointer on the scale, should show 9.2 pH value.
9. If it shows other reading, then bring the pointer to 9.2 by turning the set buffer control konb to 9.2.
10.The range selector switch is turned back to zero (or stand by) position immediately. 

 

Test for pH of water
. S
ample of water was taken in a beaker.

. Taking a pH paper strip and, holding with forceps, dip one end into the water.

.Compare the colour of the pH paper strip with the pH colour chart and find the pH of the sample.

Result: The pH of the sample is ______________ 

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

Alkalinity Water Test

Product Code: RXSOL-60-5515-003

Product Short Description

Alkalinity TEST FOR BOILER and COOLING WATER

Remarks

Avoid contact with EYE / Hand and other CHEMICALS and Gases.
 

For determination of Hydroxide alkalinity only, barium chloride is added prior to titration to precipitate the carbonate ions.  Titration is then taken only to the phenolphthalein end point.  A pH meter may be used instead of the indicators to determine the end points of the titration.

Other Equivalent Brand

Alkalinity Of Water

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...